S.NO. | Name of the Laboratory | Number of the student per setup(Batch Size) | Name of the Important Equipment | Weekly utilization on status (all the courses for which the lab is utilized) | Technical manpower Support |
Name of the Technical staff Designation Qualification | |||||
1 | Building Material & Construction Lab | 30 | 1.Vicat Apparatus 2.Vicat Needle 3.Weighing Machine 4.Trowel 5.Seive 6.Le-Chatalier’s Apparatus 7.Air Permeability Apparatus 8.Measuring Cylinder 9.Universal Testing Machine 10. Pan type Concrete Mixer 0.5 m3 11.Cube Mould (70.6*70.6*70.6 mm) 12. Aggregate Crushing Value Apparatus 13. Sieve Shaker 14.Vernier Callipers | 4 hours | Mr. Vikash Singh Lab Assistant Diploma (CE) |
2 | Concrete Technology Lab | 30 | 1.Slump Cone Apparatus 2.Tamping Rod (Graduated& Non-Graduated) 3.Cube Mould(15*15*15cm) 4.Compressive Testing Machine 5.Spliting Tensile Test Cylinder Mould 6.Vibrating Table 7.Vibrater with Nozzle(40mm) 8.Beam Mould (70*15*15) 9.Compaction Factor Testing Machine 10.Flexure Testing Machine 11.Shrinkage Bar Mould Briquette 12.Density Basket & Measuring Cylinder 13.Humidity Oven 14.GI Tray 15.Hot Air Oven 16.Sedimentation Pipette & Jar Apparatus | 4 hours | Mr. Vikash Singh Lab Assistant Diploma (CE) |
3 | Geotechnical Engineering Lab | 30 | 1. Balance 2. Sieve Set with Lid & Pan 3. Sieve Shaker (Motorized) 4.Hydrometer 5.Measuring Cylinder 6.Liquid Limit Apparatus 7.Porcilin Dish 8.Porous stone 9.Shrinkage Limit Apparatus 10. Proctor Compaction Test Apparatus 11. Relative Density Apparatus 12.Core Cutter with Hammer 13.Sand Replacement Apparatus 14.Permeability Test Apparatus 15.Direct Shear Test Apparatus 16.Static Cone Penetration Test Apparatus 17.SPT & DCPT Apparatus 18. Digital Consolidation Testing Machine 19. Digital Triaxial Testing Machine 20. Digital CBR Testing Machine 21. Direct Sheer test machine 22. V.C.S. Machine 23. Consolidation Testing 24. Automatic Compactor 25. Permeability Test Apparatus 26. Sample ejector 27. Height speed stirrer 28. Vane shear Test Apparatus. | 4 hours | Mr. Deependra Singh Instructor Diploma (CE) |
4 | Fluid Mechanics &Hydraulic Machine Lab | 30 | 1.Impact of Jet Apparatus 2. Orifice Apparatus 3. Flow Measurement Apparatus (Venturi meter& Orifice Meter) 4.Bend Meter 5.Reynold Apparatus 6. Pitot Static Tube Apparatus 7. Pipe Friction Apparatus 8. Open Circuit Subsonic Wind Tunnel 9.Metacentric Height Apparatus 10. Hydraulic Bench 11. Tilting Flume 12. Centrifugal Pump Test Rig 13.Francis Turbine Test Rig 14.Kaplan Turbine Test Rig 15.Pelton Wheel Turbine Test Rig 16.Techometer 17. Stop watch | 4 hours | Mr. Amit Rajbhar Instructor Diploma (CE) |
5 | Surveying Lab | 30 | 1.Theodolite 2. I O P Level 3. Dumpy Level 4. Auto Level 5.Levelling Staff 6.Prismatic Compass 7. Surveyor Compass 8. Planimeter 9.Cross Staff 10.Optical Square 11.Substance Bar 12.Plane Table Complete Set 13.Measuring Chain 14.Measuring Tape 15.Ranging Rod 16.Electronic Theodolite 17.Micro Optic Theodolite 18.EDM 19.Total Station with Software- 03 | 4 hours | Mr. Ajeet Yadav Lab Assistant Diploma (CE) |
6 | Geo-Informatics Lab | 30 | 1.Mirror Stereoscope Parallel Bar 2.Pocket Stereoscope 3.Satellite Data (FCC) 4.G.P.S. (Hand Held) 5.Computer with Ups 6.Scanner with Colour Printer 7.GIS Software Arc GIS 9.3 (Single User) | 4 hours | Mr. Ajeet Yadav Instructor Diploma (CE) |
7 | CAD Lab | 30 | 1.Computer 2.Ploter Printer 3.Softwares | 4 hours | Prabhakant Kundan Lab Assistant Diploma (CE) |
8 | Structure Analysis Lab | 30 | 1.Universal Frame 2.Plate Forms with Pave & Bearing 3.Bending Moment & Shear Force 4.Continuous Beam 5.Deflection of Curved Beam 6. Elastic Beam 7.Portal Frame 8.Suspension Bridge 9.Shear Centre 10.Two Hinged Arch 11.Three Hinged Arch 12.Spring Balance 13.Dial Gauge | Mr.Vikash Singh Lab Assistant Diploma (CE) | |
9 | Transportation Engineering Lab | 30 | 1. Flash & Fire Point Apparatus 2. G.I. Sheet Sieve 3.Height Speed Grinder 4. Loss Angels Abrasion Testing Machine 5. Viscometer 6. Ring & Ball Apparatus 7. Standard Penetrometer 8.Aggregate Impact Tester 9.Water Bath 10.Ductility Testing Machine 11.Float Test Apparatus 12.Marshal Stability Testing Machine 13.Benkleman Beam 14.Field CBR Apparatus 15.Length Gauge& Thickness Gauge 16.Wire Basket 17. Hot Air Over 18. Digital Electronic Balance 19. Lab Stirrer. | Prabhakant Kundan Lab Assistant Diploma (CE) | |
10 | Environmental Engineering Lab | 30 | 1.Turbidity Meter 2.Colour Comparator 3.Conductivity Meter 4.Sound Level Meter 5.PH Meter 6.Distilled Water Plant 7.Biological Microscope 8.B.O.D. Incubator 9.Hot Air Oven 10.Kheldahl Nitrogen Assembly 11.Flouride Testing Kid 12.Beaker, Burette, Funnel, Pipette, Burette Stand 13.Measuring Cylinder, Conical Flask, Measuring Flask, Watch Claris, Spatula, 14.Sprit Lamp, Burner Stand, Flap For Spirit Lamp, Glass Rod, B.O.D. Bottle 15.Hydrochloric Acid, Sulphuric Acid, 16.Methyle Drawee Indicator, Phenolphthalein Indicator 17.Nessler’s Reagent, Chlorine Water, Sodium Hydroxide, Silver Nitrate, Potassium Chromate, Ammonium Chloride Ammonia Liquid, EDTA, Magnesium Chloride, Calcium Chloride 18.Magnoussulphate, Potassium thiosulphate, Sodium Thiosulphate, Starch, 19.Di-Hydrogen Potassium Phosphate, Magnesium Sulphate, 20.Ferric Chloride, Potassium Dichromate, Ferrous Sulphate, Ferrous Ammonium Sulphate, Di-Sodium Hydrogen Phosphate 21.Lab Refrigerator – Capacities range from 1.7 to 20 cubic feet. Refrigerator temperatures range from 20 to 70C (360 to 450F). Freezer temperatures from -260 to 00C (-150to 320F). 22. COMBINED SAMPLER (PM10+PM2.5)- COMBINED SAMPLER (PM10+PM2.5) Should be Consist of: Inbuilt battery operated • Particle size: Omni-directional air inlet with PM 10 separation through an impact or followed by PM 2.5 separations through a wins impact or. • Sampling rate: Constant sampling rate of 1m3/hour unaffected by voltage fluctuation and filter choking maintained by critical orifice system . • Filter media: Filter holder designed to accept any standard 47 diameter filter media. • Sample volume: Dry gas meter record the total air volume sampled . • Power Requirement: Single phase AC 220 volts,50 Hertz supply .sampler unaffected by +/- 10% fluctuation in supply voltage 23 Jar Test Apparatus- salient features should be as per below: . Stainless steel, Up to 200rpm speed, Jar capacity 1-2 lit. , Voltage: 220-230 , Speed: Up to 200 rpm , Application : Water treatment plant , Weight: 40 kg 24. TDS Meter- Salient features should be as per below: Digital TDS Meter LED, Display along with TDS cell · Display TDS: Dual Display LED Digit & LCD L 16*2 alpha numeric · Range: 0- 1000 ppt · Accuracy: ±0.5%±1 digit · Range Selection: Automatic · Temperature Comp. : Manual digital Settable · Temperature Indication: 0 to 100ºC · Cell Constant : Adjustable(0.05-10.5) · Temp. Co-Eff.: Adjustable(0.1-4.0%) · Keyboard: Soft Touch Switches 25. Nephelometer- Digital Nephelometer /Turbidity Meter technical specifications: · Detector: Photodiode · Accessories: Flat Bottom Test tubes-(25mm) 4Nos.& Light Shield. · Accuracy: +/-3% of FSD in 0-10 &1-10 NTU. · Calibration: Fomazine Standard Solution · Dimension:W265*D300*H170mm · Display: 3 ½ Digit . · Power : 230V AC +/-10%,50Hz. · Range: 0-100NTU in 4Range (Automatic) 26. Dissolved Oxygen Meter- Should consist of the following technical specifications: Resolution=0.1/0.01pH , COLOUR-White · Measuring Range: -2.00~19.99pH · Material : Polyesters · Accuracy : ±0.2+1Digit · ATC: 0 to 50ºC · MSC: 0-50 ppt · MAC: 0-20000ft · Power DC: 1.5V*4battery Size: AAA/ UM-4 · Dimensions: Meter:195*40*36 mm kit: 230*205*50mm · Weight: Meter :135g(with battery), Gross:800 27. Water Bath- Should consist of the following technical specifications: · Temp. Display: LED display for set value (SV) & process Value (PV) · Temp. Cantrell: By Microprocessor Based PID · Voltage: 220/230 volt AC · Diffuser Shelf: Heater protective perforated cover made of stainless steel · Heating Load : 1.5 KW(1.0KW+0.5KW) · Stirring Speed: Can be Regulated by speed regulator · Stirring Arrangement: By FHP stirrer fitted with stain less steel shaft & blades · Temp.Range : ambient +5 Deg. C to 95Deg.C · Temp. Accuracy : +/-1 Degree Celsius 28. Desiccators- Desiccators 150mm Borosil with Vacuum Pump 29. 29. Air Compressor- Cooling Method Air Cooled, Capacity 192 L/min, Dimension 57 X 28 X 59 cm, Input 230 V, Motor Power 2 Hp, 1.5 Kw, Motor Speed 3400 rpm 30.Wash bottle- Wash bottle 500ml. Cap, poly 31.Digital Laboratory Oven- Laboratory electric oven with digital indicator cum controller with safety alarm, Range 50 deg to 250 deg C+/- 1 deg C with Air circulating fans inside size 600*900*600 32.Digital COD Digester- Display: Digital 12 mm Rod LED Time: Selectable 15,30,45,60,90 or 120 min with alarm Heater Rating (W): 750 Watts Sensor: PT-100 Hole Size (mm): 40 mm dia c 80 mm depth Control: Digital electronic Temperature Controller Sample Volume (ml): 20 ml, Each Glass Tube (mm): 38 mm dia 15 nos (5×3 rows) Temperature Range: Above amb To 180 degC or higher Resolution: 1deg C Dimension: 500 W x 270 D x 210 mm H 33.Kjeldahl Distillation apparatus- Kjeldahl Apparatus: Combined Kjeldhal Digestion & Distillation Unit “Electrically heated, comprising of one single mild steel tubular stand provided with two shelves one above the other. A specially designed glass fume duct with B 24) Cone openings (suitable for flasks having 24/29 socket) having such provision so that no leakage of fumes takes place. One heater box having individual energy regulators for 500 watts heaters are supplied in digestion part at the lower side. One heater box of above design is supplied in distillation part at the upper side. Distillation part is also provided with brass condenser rack with water circulation systems and clamps. The whole unit is operated on 220 volts AC mains.” Complete unit without glass parts for 6 tests 34. Electronic Weighing Balance- Digital Balance 220gm – 1mg, High-precision Electromagnetic Balances, Capacity: 220Gm., Minimum display: 0.001g, Repeatability (standard deviation): σ≤0.001g, Display: LCD “Response time :1.0−1.2 sec., Linearity: ±0.002g, Ambient temperature: 5−40°C, Temperature coefficient of sensitivity (10−35°C): ±3ppm/°C” 35.Electric Muffle furnace- Electric Muffle furnace (Max-1200*C, working Temp 1150) with Digital Temp Indicator cum controller, CE Certified 150x150x300mm 36. Spectrophotometer- UV -VIS. Spectrophotometer Baseline Flatness ±0.0010A, 200-800 nm, 1.0nm SBW, smoothing Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1 nm DescriptionCutting-edge instrumentation, intuitive and powerful software, and a wide range of accessories consistently deliver high quality results and improved productivity Detector TypeDual Silicon Photodiodes Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in) DisplayNone Drift<0.0005A/hr, 500nm, 1.0nm SBW, 1 hr warm-up Electrical Requirements100-240V 50-60Hz, selected automatically, 150W maximum Item DescriptionEvolution 220 UV-Vis Spectrophotometer, Computer Control, includes Euro/US/UK power cords KeypadSealed membrane LampXenon Flash Lamp, 3-year warranty (7 years typical lifetime) 37. Pipette bulb- rubber 38. filter paper- Whatman for PM10 &PM2.5 39. Laboratory Steam Bath apparatus- Classification: Laboratory Thermostatic Devices Laboratory Steam Bath Type: 6 holes Material: Stainless Steel Size: 450x300x130mm Power: 1200W Temperature range: RT-99.9-degree Weight: 9kg 40.Porcelain Evaporating Dishes – 75mm dia 41.Imhoff Cone with Rack- glassware 42.Methyl Orange- chemical 43.Micropipette Variable volume- Glassware (range 0.1 ul~10ml) 44.Phosphate Buffer Solution (Buffer soln 7 Ph Phosphate)- chemical 45.Sodium Sulphite Solution- chemical 46.Alkali Iodide Azide Regent (Potassium Iodide)- chemical 47.Alum Solution (for TLC)- chemical 48.Lime- chemical 49.Mercuric Sulphate- chemical 50.Ferroin Indicator- chemical 51.Sulphuric Acid Crystal- chemical | 4 hours | Mr. Ajeet Yadav Instructor Diploma (CE) |
11 | BPD lab | 30 | In Process | Mr. Amit Rajbhar Lab Technician Diploma (CE) | |
12 | NDT Lab | 30 | Rebound Hammer Rest of Purchase |